The QCX series bearing block load cell is mainly installed under the bearing housing and can also be used in other structural forms. It is a dedicated sensor mainly for measuring the bearing capacity of a certain type of bearing housing.
Le principe structurel Il s'agit d'un capteur de contrainte à résistance de cisaillement dont les deux extrémités sont fixées et le palier central. Le corps élastique est en acier allié de haute qualité et les jauges de contrainte à résistance de type feuille sont des éléments de conversion sensibles.
The socket is installed in the middle of the sensor, and the two ends of the sensor are fixed on the base. When the bearing housing is in load, the load is transmitted to the base through the shear elastic beams at both ends, generating strain proportional to the load in the elastic beams, which is converted into corresponding electrical signals by strain gauges.
Percevoir le monde Connecter le monde Innover le SUNMOON
Description
The QCX series bearing block load cell is mainly installed under the bearing housing and can also be used in other structural forms. It is a dedicated sensor mainly for measuring the bearing capacity of a certain type of bearing housing.
Le principe structurel Il s'agit d'un capteur de contrainte à résistance de cisaillement dont les deux extrémités sont fixées et le palier central. Le corps élastique est en acier allié de haute qualité et les jauges de contrainte à résistance de type feuille sont des éléments de conversion sensibles.
The socket is installed in the middle of the sensor, and the two ends of the sensor are fixed on the base. When the bearing housing is in load, the load is transmitted to the base through the shear elastic beams at both ends, generating strain proportional to the load in the elastic beams, which is converted into corresponding electrical signals by strain gauges.
Caractéristiques
1. Strong anti-interference ability, is convenient to install and use, and has good stability.
2. The flat plate shape ensures a stable force state, good lateral interference, and can achieve high measurement accuracy.
3. Strong overload capacity and used for overload alarm of bridge cranes.
Dimensions (en mm. 1 mm = 0,03937 pouce)
CHAVIRER
UN
B
C
D
L
L1
L2
ØH
t/mm
1.5
350
310
38
75
152
100
40
17
2.5
410
355
50
100
182
130
60
21
4、8、10
410
355
50
100
212
160
60
21
15、20
457
387
50
100
212
160
60
M24
Ib/pouces (conversion des dimensions ci-dessus)
3306.93
137.80
122.05
14.96
29.53
59.84
39.37
15.75
6.69
5511.56
161.42
139.76
19.69
39.37
71.65
51.18
23.62
8.27
8818.49、17636.98、22046.23
161.42
139.76
19.69
39.37
83.46
62.99
23.62
8.27
33069.34、44092.45
179.92
152.36
19.69
39.37
83.46
62.99
23.62
M24
Schéma de circuit :
Rouge : + entrée
Bleu : -entrée
Blanc : + sortie
Jaune : -sortie
Spécification:
Taper
Paramètres techniques
Plage de charge nominale
1.5~30t
Alimentation électrique
10 à 12 V CC
Solde nul
1,0±% de la puissance de sortie nominale
Sortie analogique
2,0±0,01 mV/V
Résistance d'entrée (Rlc)
400±20Ω (ohms)
Résistance de sortie (Ro)
350±5Ω (ohms)
Résistance d'isolement
≥ 5000 MΩ (Méga-Ohms)
Précision de la classe
0,1%FS
Effet de la température
0,02%FS/10℃
Température de fonctionnement
-40~+85℃
Limite de charge sécuritaire
200% FS
Marge de sécurité contre le rendement
300% FS
Marge de sécurité contre la casse
500% FS
Matériau Matériau
Acier allié haute performance ou acier inoxydable (taux de chrome>15%)